APPROVAL
Test standard IEC/ EN60998 / UL1059
Pitch [mm] 3.81
Poles 06-72P
IEC60998 Test data /
Rated voltage [V] 160
Rated current [A] 12
Rated connection capacity solid/stranded [mm²] 0.2-1.5
Surge voltage category/pollution degree/material group III/2/I
Withstanding Voltage [KV/min] 2.5
Rated torque [N.m] 0.2
UL1059Test data UL File Number E228872
Use group B C D
Rated voltage [V] 300 / /
Rated current [A] 12 / /
Rated connection capacity solid/stranded [AWG] 30-16
Rated torque [Lb. in] 1.77
General data /
Screw M2
Inflammability classUL94 V-0
Ambient temperature [¡æ] -40~+105
Relative humidity 5%-95%
Inspection standard MIL-STD-105E II
AQL 0.65
Warranty 12 months
Material and plating /
Housing PA66
Screws Steel£¬Zn plated
Contact Copper alloy£¬Sn plated
Cage Copper alloy£¬Ni plated
Wire connecting
5-6mm; Recommended stripping length 5-6mm;
1.£©For solid wire, stripping wire to the appointed length, then tightening with rated torque.
2.£©For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.